PRODUCT

Accessories​

Enhance the performance, safety, and convenience of your automatic door system with a wide range of compatible accessories. Designed for seamless integration, these components improve functionality, user experience, and overall system reliability for various applications.

Scroll to Top

NS-A01 TRANSOM MOUNT SENSOR

It is a kind of automatic door probe that integrates Japanese technology, peace of mind, safety and comfort.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
4.0m
Maximum Detection Area
5.2m width x 3.3m depth (reference value)
Power Consumption
<DC12V 120mA
Remarks
Set with independent area, so as to correspond to irregular doors; Be configured with self-diagnosis and non-touch sensing functions; Be equipped with snow and insect prevention measures as well as eco mode.

NSW-A01 TRANSOM MOUNT SENSOR

The combined use of infrared and image sensors, the sensor detection area has expanded 4 times. This new sensor precisely detects the movement of people and open only for people wanting to pass through.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
3.5m
Maximum Detection Area
5m width x 4m depth (reference value)
Power Consumption
<DC12V 200mA
Remarks
Have self-diagnosis function; Full color LED light action

OA-215V TRANSOM MOUNT SENSOR

It detects objects through the reflected invisible light. Based on its quick detection, it can detect both dynamic and static objects. It is a kind of product widely used in Japan.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
3.0m
Maximum Detection Area
4.0m width x 3.2m depth (reference value)
Supply Voltage
12-110V AC/DC±10%
Power Consumption
<2.0W (<5VA/AC)
Remarks
Have self-diagnosis function

NS-A02 TRANSOM EMBEDDED SENSOR

It is a kind of automatic door probe that integrates Japanese technology, peace of mind, safety and comfort.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
4.0m
Maximum Detection Area
5.2m width x 3.3m depth (reference value)
Power Consumption
<DC12V 120mA
Remarks
Set with independent area, so as to correspond to irregular doors; Be configured with self-diagnosis and non-touch sensing functions; Be equipped with snow and insect prevention measures as well as eco mode.

NS-A04 CEILING MOUNT SENSOR

As a ceiling mounted product, it can be installed on the ceiling close to the door body, thus expanding the design freedom. In addition, it is integrated with ceiling spotlights to improve the overall aesthetics. Based on its convenient installation and dismantling, it is another popular sensor after the beam-mounted type.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
4.0m
Maximum Detection Area
3.2m width x 3.2m depth (reference value)
Power Consumption
<DC12V 700mA
Remarks
Have self-diagnosis function

NH-721 CEILING MOUNT SENSOR FOR SUPER HIGH DOOR

It us specially used for super high doors up to 5m and is installed on ceiling.

Detection Mode Near infrared reflection mode (dynamic & static induction)
Maximum Installation Height
4.0-5.0m
Maximum Detection Area
5.2m width x 3.3m depth (reference value)
Power Consumption
<DC12V 120mA
Remarks
Set with independent area, so as to correspond to irregular doors; Be configured with self-diagnosis and non-touch sensing functions; Be equipped with snow and insect prevention measures as well as eco mode.

HW-NC PROXIMITY SENSOR (NON-CONTACT)

  • Standard 86 type switch panel with wireless/wired design, ensuring more flexible installation.
  • The transmitter is designed with low-power emission technology, ensuring long transmis- sion distance, low power consumption and long battery service life.
  • The blue light will be on if the remote control is valid, which can be used to confirm whether the switching is valid.
  • Adjustable sensing distance (3-30cm).

HW-TC TOUCH SENSOR

A wireless transmitter is built into the touch pad, allowing it to send signals to the receiver connected to the door operator when tapped. This enables automatic door opening and closing without the need for signal cables, reducing installation complexity—only a mounting hole is required.

Detection Mode Pressurization Detection (compression plate)
Information mode
Radio wave (310MHZ)
Standard Wireless Transmission Distance
5.0m
Maximum Detection Area
Receiver: <AC80-20V 2VA, <DC12/24V 50mA Transmitter: 7# alkaline battery
Output Capacity
Output contact 1a DC50V/0.1A(resistive load)

FT-80B FOOT SWITCH

Facilities related to hospitals and food can use the kicking sensor to open automatic doors; The kicking sensor is usually suitable for airtight doors (NAX series) and ordinary medical automatic doors.

Detection Mode Photoelectric mode
Operational mode
Foot inserting
Power Consumption
<AC100V 2VA
Output Capacity
AC100V 0.5A (resistive load) DC24V 1.0A (resistive load)
Remarks
Operating force 0 N

NP-01 SAFETY BEAM

The starting sensor of automatic door is mainly used to start the equipment, while the auxiliary sensor is to protect the object passing or staying in the door body from being pinched, thus improving the safety of automatic door.

Detection Mode Dynamic, static detection (Single light ray)
Installation Height
Standard FL (Ground) +600
Maximum Detection Area
Light projector/ receptor distance 5.0m
Power Consumption
<DC12V 50mA
Output Capacity
Collector output DC30V 0.1A (Resistive load)

PL-T10U DRIVEN PULLEY LOCK

The driven pulley electromagnetic lock locks the special drive belt automatic foot, so as to keep the automatic door leaf closed. Since its components operate with low sound and low failure rate, it can be used safely.

Unlock Feature Power Failure Release
Unlock Construction
Electromagnetic lock
Input signal
1A current, automatic door linking
Indicator Light
Release light red, displayed on the controller
Unlock monitoring output
No voltage A power supply
Remarks
Be used with PLC-N controller

SKD-T10U ELECTRONIC LOCK

Input Power Supply AC100V/1A
Electronic lock current consumption
Starting state: 900mA Normal State: 350mA
Door lock delay time
0-9s (can be set by the user), factory value: 2.5s
Signal Output
Used to trigger automatic door, normally open contact output (N.O) to withstand 1A current
Safety Measures
1. Power-off open safety electronic lock; 2. There is optical coupling opening input button contact built in, if the door is not opened within 5 seconds, it will automatically be locked again.
Sensor signal delay time
After the sensor detects the electronic lock stopper, the signal holding time can be adjusted on the electric lock.

PGS PROGRAM SWITCH

A small wall-mount switch is added to make the automatic door be used more easily. This new type of switch is simple to operate, and can be switched repeatedly at will according to the needs of users. Besides, its security protection with a lock can effectively prevent irrelevant personnel from changing its operation mode.

APS-A10 PROGRAM SWITCH

  • Color LCD display, providing excellent vision for door opening and closing.
  • Can quickly and easily change the door status, such as opening/closing speed and opening holding time and so on.
  • Can quickly access to door details, making maintenance and troubleshooting easier and faster.
  • Multiple languages available, including Chinese, English, Korean, Thai, Vietnamese, Indonesian and Russian.
  • Dimensions: 88×88×16.5 mm

EBS EMERGENCY OPERATING SYSTEM

EBS is the emergency power supply device for NET-VS series automatic doors. In case of power failure or emergency signal (DC24V) input, the drive power of the automatic door is provided by the built-in power supply to keep the automatic door open (or closed). After the normal power supply is restored, the automatic door will be restored to the state before power failure, and after the emergency signal is released, the reset switch will be switched on to return to the normal state of use.

  • The device is built in the electromechanical beam, with the features of compact structure and convenient installation.
  • You can choose to provide normally open or normally closed signal to the automatic door in case of power failure or emergency signal input, so that the automatic door is open or closed.
  • The charging and power working status LED indicators are set on the body, which is convenient to confirm the power supply status and battery working status.
  • The emergency power supply adopts small fully-sealed and maintenance-free Ni-Cd battery.
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.